Instructions for use: step-by-step medical guidance

Clinical context and indications for the TechRing, MaxPR and Performance rings, plus patient instructions for setup, recording, uploading, light codes and troubleshooting.

FirmTech product line: descriptions of each of our products are in this document: Product descriptions.

Section 1: For health care providers

Clinical context and indications

The TechRing (smart monitoring device)

  • Primary function: erectile function assessment via pressure sensor and strain gauge technology; venous leak prevention
  • Clinical applications: NPT monitoring for psychogenic vs. organic ED differentiation; treatment response quantification (PDE5 inhibitors, testosterone replacement, cardiovascular interventions); cardiovascular risk screening
  • Data output: firmness scale 0–10.0, duration, frequency, Erectile Fitness Score
  • Validation: clinically consistent with the RigiScan gold standard; FDA-registered Class II, 510(k)-exempt medical device
  • Clinical endorsement: Dr. Mohit Khera, M.D., M.B.A., M.P.H. (former president, Sexual Medicine Society of North America)

MaxPR and Performance rings (non-tech rings)

  • Primary function: erection ring for venous leak prevention
  • Clinical applications: erectile dysfunction, particularly sustaining erections
  • Validation: FDA-registered Class II, 510(k)-exempt medical device
  • Clinical endorsement: Dr. Mohit Khera, M.D., M.B.A., M.P.H. (former president, Sexual Medicine Society of North America)

Section 2: For patients

Product A: The TechRing

Detailed patient instructions for the TechRing are also available in the help center.

Pre-use setup

Battery management:

  • Charge fully before first use (minimum 60–70% for 8-hour recordings).
  • Charging indicators: red blinking → solid green when complete.
  • Important: wrap the ring clockwise around the charger, as marked on the device.

App installation:

  • Download the app from the app page (iOS/Android).
  • All data are anonymized and shared only with explicit authorization to a physician or tech support.

TechRing operation protocol

Step 1: Device activation

  1. Short-press the power button (on the side of the ring).
  2. Confirm the blue light (device powered on).

Step 2: Bluetooth pairing

  1. Open the FirmTech app.
  2. Tap “PAIR” or “PAIR TECHRING”.
  3. Wait for a solid blue light (confirms connection).

Step 3: Starting a recording

  1. Tap “RECORD NOW” in the app.
  2. Look for 10 green flashes (confirms the recording has started).
  3. The app displays “Recording in Progress - Unpaired”.
    • Normal behavior: Bluetooth disconnects during recording, so the device does not transmit while it is worn.

Step 4: Device placement

  1. Calibration period: allow 10–15 minutes for the pressure sensor to adjust before activity.
  2. Unhook the ring and stretch the loop open.
  3. Placement: position the testicles through the loop (penoscrotal placement).
  4. Latch the hook around the base of the shaft.
  5. Adjust the tension for comfort.

Device safety:

  • The ring is designed not to restrict arterial inflow.
  • It can be worn in the flaccid or erect state.
  • Use only water-based or silicone lubricants (natural oils damage the device).

Step 5: Ending a recording

  1. Press and hold the power button for 3 seconds.
  2. Look for 3 red flashes (recording stopped, device off).

Step 6: Data upload

  1. Short-press the power button (turns the device on).
  2. Open the app and tap “PAIR”.
  3. Confirm the solid blue light.
  4. A blue progress bar appears (automatic upload).
  5. Complete the questionnaire: medications, alcohol, substances, clinical notes.

Step 7: Erection classification

  1. Tap the “Classify” icon on the home screen.
  2. Categorize the detected erections: Sleep / Solo / Partnered Sex / Other.
  3. Required: statistics populate only after classification is complete.
  4. When finished, “Classify” changes to “Classified”.

TechRing light indicator reference

Light pattern Meaning
Flashing blue Device on, not paired
Solid blue Device on, paired to phone
10 green flashes Recording started
Single green flash (during recording) Confirmation signal
Pulsing red (off charger) Low battery warning
3 red flashes Recording stopped, device off
Solid green (on charger) Fully charged

TechRing troubleshooting

Issue Solution
A short recording shows “Recording in Progress” indefinitely Ignore the message and end the recording as normal (steps 5–6).
Upload fails Check the battery is above 20%, keep the ring within 10 feet of the phone, and restart the app.
Erection not detected Make sure the 10–15 minute calibration period was completed, and check that the pressure sensor (hook) is positioned on the ventral surface of the penis.

Data management:

  • Deleting recordings: open the recording list → press and hold the unwanted recording → confirm deletion.

Product B: MaxPR and Performance rings

  1. Unhook the ring and stretch the loop open.
  2. Placement: position the testicles through the loop (penoscrotal placement).
  3. Latch the hook around the base of the shaft.
  4. Adjust the tension for comfort.
  5. The Performance ring can be worn all night; the MaxPR no more than 90 minutes.
  6. Do not use oils with the rings; use only water- or silicone-based lubricants.